To post questions, help other DIYers and reduce advertising like the one on your leftjoin our DIY community. We welcome your comments and suggestions. All information is provided "AS IS. Questions of a Do It Yourself nature should be submitted to our " DoItYourself. You may freely link to this site, and use it for non-commercial use subject to our terms of use.

View our Privacy Policy here. Hi Unregistered Logout Connect with Facebook Login Sign Up. Temporary V patch at Breaker Panel. Welcome to the 220 hook up in panel Forums! 220 hook up in panel Tools Show Printable Version Search Thread. Join Date Mar Posts 9. Temporary V patch at Breaker Panel I have a temporary project where I need V to run a TIG welder. I do not have any V outlets accessible. Since it is only temporary, I would prefer not to add a permenant V circuit.

The breaker box is right outside my garage so it is conveniently accessible for the welder. Is there a proper way to temporarily run a V service at the breaker box? Join Date Sep State NY Posts 13, Install a volt breaker of the proper size and run the proper size wire for the welder to a properly installed receptacle. There is no other way to do this. Join Date Sep Posts 18, If you really have no volt receptacle now e. 220 hook up in panel only take you minutes to wire it up.

You can certainly make it temporary if you want. When your're done, spend another minutes removing what you put in. Join Date Jan Posts 1, As Racraft says, you need to install a proper circuit breaker, run proper cables, and install a proper receptacle. 220 hook up in panel other words, you need to install a proper circuit. For example, if your welder needs a 50A circuit, and you have a 50A range breaker, then eat out for the evening and use that. If the range is fed with aluminium conductors, then study up on proper termination of these.

You could even use flexible cord, normally prohibited for building wire, however then you would need a breaker that properly terminates the fine stranding of the flexible conductors. You must still use a proper fitting to support the cable going through the side of the panel. Basically you don't have to spend 220 hook up in panel of time stapling and routing the cable, simply make sure that it is protected from damage.

See article for details on temporary installations. Basically you get a little more leeway, but for the most part the standard wiring rules obtain. After you are finished, be sure to use a proper plug to seal any holes that you open in your breaker panel. Thanks for the suggestions guys. It's probably more difficult to access those wires then at the breaker box. The problem with the breaker box is that wall interior is not accessible from the inside not even through drywall.

If I needed to mount a gang box for a receptacle, I would need to tear through stucco. I guess what I'm asking is if it's okay to add the proper breakers and hard wire or hang a receptacle off that without intruding into the wall. Sure, you can surface mount the box. You can probably even mount the box to a temporary stand. What you describe would IMHO be a code violation. A rather common one in some areas, and possibly even reasonably safe depending upon the specifics of the situation.

At some point you will probably have to deal with ripping through the stucco anyway to run a new circuit, something to consider as a possibility. I could not recommend simply leaving the front of the panel open with exposed bus bars. However I see no issue if you could properly cover the panel after connecting the wires. You can buy heavy rubber blankets specifically designed to cover exposed electrical hardware.

No matter what you do, make sure that you can get to the breakers without risking accidentally touching the live metal. Newsletter Sign-Up Signup Email address. Find a Professional Type of Job Type of Job Additions and Remodels Appraisers and Home Inspectors Architects Bathroom Remodeling Cabinets and Countertops Carpentry Carpet Cleaning Concrete and Masonry Custom Homes Decks and Porches Decorators and Designers Doors Drywall Electrical 220 hook up in panel Fences Flooring Foundations Garage Doors Handyman HVAC Kitchen Remodeling Landscaping Moving Painting Pest Control Plumbing Roofing Siding Small Projects and Repairs Solar Energy Sunrooms Swimming Pools Tile Work Walls Windows Home Security.